BizVerify |
|
| Yanshan Shuntong Steel Pipe&fittings Co., Ltd. |
| Verified By : Huaxia D&B |
| Verified Date : 2010-05-08 |
|
 |
|
|
|
|
|
|
|
|
|
|
|
Socket-Welding Fittings
| Nominal Pipe Size |
Socket Bore Diameter, B |
Bore Diameter of Fittings, D[Note(1)] |
Socket Wall Thickness,C [Note(2)] |
Body Wall, G |
Min
Depth of
Socket, J |
| Class Designation |
Class Designation |
| Class Designation |
3000 |
6000 |
9000 |
3000 |
6000 |
9000 |
| 3000 |
6000 |
9000 |
Avg. |
Min. |
Avg. |
Min. |
Avg. |
Min. |
Min. |
Min. |
Min. |
| 1/8 |
11.2 |
7.6 |
4.8 |
… |
3.18 |
3.18 |
3.96 |
3.43 |
… |
… |
2.41 |
3.15 |
… |
9.5 |
| |
10.8 |
6.1 |
3.2 |
… |
|
|
|
|
|
|
|
|
|
|
| 1/4 |
14.6 |
10 |
7.1 |
… |
3.78 |
3.3 |
4.6 |
4.01 |
… |
… |
3.02 |
3.68 |
… |
9.5 |
| |
14.2 |
8.5 |
5.6 |
… |
|
|
|
|
|
|
|
|
|
|
| 3/8 |
18 |
13.3 |
9.9 |
… |
4.01 |
3.5 |
5.03 |
4.37 |
… |
… |
3.2 |
4.01 |
… |
9.5 |
| |
17.6 |
11.8 |
8.4 |
… |
|
|
|
|
|
|
|
|
|
|
| 1/2 |
22.2 |
16.6 |
12.5 |
7.2 |
4.67 |
4.09 |
5.97 |
5.18 |
9.35 |
8.18 |
3.73 |
4.78 |
7.47 |
9.5 |
| |
21.8 |
15 |
11 |
5.6 |
|
|
|
|
|
|
|
|
|
|
| 3/4 |
27.6 |
21.7 |
16.3 |
11.8 |
4.9 |
4.27 |
6.96 |
6.04 |
9.78 |
8.56 |
3.91 |
5.56 |
7.82 |
12.5 |
| |
27.2 |
20.2 |
14.8 |
10.3 |
|
|
|
|
|
|
|
|
|
|
| 1 |
34.3 |
27.4 |
21.5 |
16 |
5.69 |
4.98 |
7.92 |
6.93 |
11.38 |
9.96 |
4.55 |
6.35 |
9.09 |
12.5 |
| |
33.9 |
25.9 |
19.9 |
14.4 |
|
|
|
|
|
|
|
|
|
|
| 1 1/4 |
43.1 |
35.8 |
30.2 |
23.5 |
6.07 |
5.28 |
7.92 |
6.93 |
12.14 |
10.62 |
4.85 |
6.35 |
9.7 |
12.5 |
| |
42.7 |
34.3 |
28.7 |
22 |
|
|
|
|
|
|
|
|
|
|
| 1 1/2 |
49.2 |
41.6 |
34.7 |
28.7 |
6.35 |
5.54 |
8.92 |
7.8 |
12.7 |
11.12 |
5.08 |
7.14 |
10.15 |
12.5 |
| |
48.8 |
40.1 |
33.2 |
27.2 |
|
|
|
|
|
|
|
|
|
|
| 2 |
61.7 |
53.3 |
43.6 |
38.9 |
6.93 |
6.04 |
10.92 |
9.5 |
13.84 |
12.12 |
5.54 |
8.74 |
11.07 |
16 |
| |
61.2 |
51.7 |
42.1 |
37.4 |
|
|
|
|
|
|
|
|
|
|
| 2 1/2 |
74.4 |
64.2 |
… |
… |
8.76 |
7.67 |
… |
… |
… |
… |
7.01 |
… |
… |
16 |
| |
73.9 |
61.2 |
… |
… |
|
|
|
|
|
|
|
|
|
|
| 3 |
90.3 |
79.4 |
… |
… |
9.52 |
8.3 |
… |
… |
… |
… |
7.62 |
… |
… |
16 |
| |
89.8 |
76.4 |
… |
… |
|
|
|
|
|
|
|
|
|
|
| 4 |
115.7 |
103.8 |
… |
… |
10.69 |
9.35 |
… |
… |
… |
… |
8.56 |
… |
… |
19 |
| |
115.2 |
100.7 |
… |
… |
|
|
|
|
|
|
|
|
|
|
|
|
|
Nominal
Pipe Size |
Center to Bottom of Socket,A |
Laying Lengths |
Tolerances,+ |
End Wall Thickess,Kmin |
90-deg Elbows,
Tees,
and Crosses |
45-deg
elbows |
Class Designation |
| Class Designation |
Couplings,E |
Half
Couplings,F |
A |
E |
F |
3000 |
6000 |
9000 |
| 3000 |
6000 |
9000 |
3000 |
6000 |
9000 |
| 1/8 |
11 |
11 |
… |
8 |
8 |
… |
6.5 |
16 |
1 |
1.5 |
1 |
4.8 |
6.4 |
… |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1/4 |
11 |
13.5 |
… |
8 |
8 |
… |
6.5 |
16 |
1 |
1.5 |
1 |
4.8 |
6.4 |
… |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3/8 |
13.5 |
15.5 |
… |
8 |
11 |
… |
6.5 |
17.5 |
1.5 |
3 |
1.5 |
4.8 |
6.4 |
… |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1/2 |
15.5 |
19 |
25.5 |
11 |
12.5 |
15.5 |
9.5 |
22.5 |
1.5 |
3 |
1.5 |
6.4 |
7.9 |
11.2 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3/4 |
19 |
22.5 |
28.5 |
13 |
14 |
19 |
12.5 |
24 |
1.5 |
3 |
1.5 |
6.4 |
7.9 |
12.7 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
22.5 |
27 |
32 |
14 |
17.5 |
20.5 |
12.5 |
28.5 |
2 |
4 |
2 |
9.6 |
11.2 |
14.2 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 1/4 |
27 |
32 |
35 |
17.5 |
20.5 |
22.5 |
12.5 |
30 |
2 |
4 |
2 |
9.6 |
11.2 |
14.2 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 1/2 |
32 |
38 |
38 |
20.5 |
25.5 |
25.5 |
12.5 |
32 |
2 |
4 |
2 |
11.2 |
12.7 |
15.7 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 |
38 |
41 |
54 |
25.5 |
28.5 |
28.5 |
19 |
41 |
2 |
4 |
2 |
12.7 |
15.7 |
19 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 1/2 |
41 |
… |
|
28.5 |
… |
… |
19 |
43 |
2.5 |
5 |
2.5 |
15.7 |
19 |
… |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 |
57 |
… |
|
32 |
… |
… |
19 |
44.5 |
2.5 |
5 |
2.5 |
19 |
22.4 |
… |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 |
66.5 |
… |
|
41 |
… |
… |
19 |
48 |
2.5 |
5 |
2.5 |
22.4 |
28.4 |
… |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE:(1),Upper and lower values for each size are the respective maximum and minmum demensions.
(2),Average of socket wall thickness around periphery shall be no less than listed values.The minmum
values are permitted in localized areas. |
|
|
|
|
|
|
|